[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] TRNSYS-users Digest, Vol 86, Issue 31



Subject: [TRNSYS-users] Weather Data
 
Dear Mayank,
 
The weather files of indian cities are availbale in TMY2 format
in standard weather folder of TRNSYS 17 software.
 
Best Regards
Amit kakkar

On Thu, Feb 23, 2012 at 1:51 PM, <trnsys-users-request@cae.wisc.edu> wrote:
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://mailman.cae.wisc.edu/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. Weather Data (Mayank)
  2. Airnodes and use of the coupling tool (Joke De Beuckelaer)


---------- Forwarded message ----------
From: "Mayank" <mayank.23aug@gmail.com>
To: <trnsys-users@cae.wisc.edu>
Cc: 
Date: Thu, 23 Feb 2012 09:28:55 +0530
Subject: [TRNSYS-users] Weather Data

Hello Everyone,

 

Where will I get weather data of INDIAN Cities in .tmy or .tm2 format or can I convert epw, IWEC file into these format?

 

Thank you in advance.

 

Regards,

 

Mayank

 



---------- Forwarded message ----------
From: Joke De Beuckelaer <joke.d@vkgroup.be>
To: trnsys-users <trnsys-users@cae.wisc.edu>
Cc: 
Date: Thu, 23 Feb 2012 08:02:24 +0000
Subject: [TRNSYS-users] Airnodes and use of the coupling tool

Dear all,

 

I’m modeling a landscape office. Because I want to measure the temperature at different places, I divided the landscape office in different air nodes.

 

In attachment, you can find a simplified drawing.

 

I was wondering if my assumptions for the model are correct:

-       Situation 1: pulsion of fresh air in two air nodes of the office and extraction in the corridor (still part of the landscape office)

·         Is it correct to model this situation like mentioned in the attachment? (vent = ventilation defined)

·         Some questions:

o    In the case of cross-ventilation, by the coupling tool do you have to consider the “upper” or the “lower” part?

o    For air node 3 is it necessary to define and the coupling and the ventilation? Or is one of these two sufficient?

When you have to define the coupling, is het possible to indicate that a certain air flow is received from different adjacent air nodes?

 

-       Situation 2: pulsion of fresh air in two air nodes of the office and extraction in the corridor which is a different zone now.

·         Is it correct to model this situation like mentioned in the attachment?

 

 

If you have any questions or if my question isn’t very clear, don’t hesitate to contact me.

 

 

Thanks in advance,

 

Joke De Beuckelaer

project engineer mep

 

 

VK     HEALTHCARE          BUILDINGS      |      INDUSTRY          INFRA

 

Value by design

 

VK ENGINEERING  Avenue Clemenceaulaan 87, 1070 Bruxelles Brussel, Belgium  
t   +32 2 414 07 77   f  +32 2 414 04 98   m  +32 473 97 01 50   e   joke.d@vkgroup.be   w   www.vkgroup.be

 

 

 ALWAYS LOOKING FOR GREAT PEOPLE       

****DISCLAIMER****
This communication is confidential and for the sole useof the addressee. If you are not the intended recipient,
please immediately notify the sender by e-mail at the address shown and then delete it from your system
without copying, disclosing or forwarding its contents. Thank you.

 

 


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users