Re: [TRNSYS-users] regarding the problem of using type 194 without inverter



Guang Yu,
  please send the Simulation Studio project file (*.tpf) that you are running.
Kind regards,
 David


On 10/13/2011 23:02, Guang Yu Jin wrote:

Dear TRNSYS users,

 

I encounter some problem when using type 194 (PV model). I configure the parameter of

Vmaxp = 42

I maxp = 5.16

 

So the max power at the reference condition (25C, 1000W/m^2) is 42*5.16 =216 W

But the output of the type 194, for 1 pc of PV module, the  “Power at Mzximum Power Point” goes to 1000W+. That is impossible

Is any users can teach me where the problem is?

 

Thanks & Best Regards,

GY

----------------------------------------------------------