Jun-Won, In order to change a PARAMETER to an INPUT, you need to use a Fortran compiler (ideally the Intel Visual Fortran compiler v9 or greater because the ..\TrnsysXX\Compilers\ directory includes recompile projects for this compiler). You would need to open (or recreate) a Fortran project that contains Type687. You would then need to edit the Type's source code, recompile Type687 and relink the DLL. Lastly, you would need to change the Type687 Simulation Studio proforma to reflect the change and perform an Edit: Replace on the component in your existing projects. Kind regards, David On 10/5/2011 22:02, 박준원 wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |