Mayank,
  In order to add an output to a component, you need to modify the Type's source code and recompile the TRNDll using a Fortran compiler. Actually changing an input variable to an output variable is a fairly complex procedure because by definition, the component's performance depends on its input values. In this case, the performance of your collector depends on the collector area. If you want to change the area from an input to an output, you also need to figure out how you are going to calculate the collector performance without without knowing the collector area in advance.
Best,
 David
 

On 9/7/2011 00:23, Mayank Bhatnagar wrote:

Hello everyone,

I am working on solar vapor absorption machine. For this I have to make some changes in TYPE 73 FPC input output. I need collector area in output. How can I change input to output please help me out.

 

Thank you

 

Mayank Bhatnagar

M.Tech. (Energy Engineering)

Malaviya National Institute of Technology,

Jaipur (INDIA)

contact no.- +91-9983816468

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com