Oswaldo,
I had understood from your first email that you were getting an error when opening a proforma on the target machine (ie nothing to do with actually running a simulation). Some of the other responses have been aimed at solving a run-time problem (in other words you can implement the proforma in a new project on the target machine but you get an error when you run the simulation. Can you please clarify?
Kind regards,
David
On 8/24/2011 14:17, Oswaldo Hidalgo Barrientos wrote:_______________________________________________ TRNSYS-users mailing listHi Christiana and users, thanks so much
Really, i dont know if target machines, have the microsoft VC++ redist pack libs installed or updated...I will check...but i have other question with the above, does this is without regardless if my new component was developed in Compac Visual Fortran 6?....also I have the problem that target machines are conected from a internal network and are managed by a server machine....do should copy the new component (dll and proforms) in the server machine or in every target machine?Regards
Oswaldo
2011/8/23 Christian Glück <christian.glueck@kit.edu>
Hi Oswaldo,
do you have the Micro$oft VC++ redist pack libs installed on the target computer?
I've had a similar problem once, it's here: https://mailman.cae.wisc.edu/pipermail/trnsys-users/2010/005826.html
Maybe that's it.
Regards,
Christian
On 08/23/2011 07:00 PM, trnsys-users-request@cae.wisc.edu wrote:
Dear all.
I am trying copy in other computers a new component developed in my laptop ...I copy the file ".dll" in /trnsys17/userlib/ReleaseDLLS and the files ".tmf" (proforma) to copy in trnsys17/studio/proformas/new folder.....anyway, I do all this stuff....once
open the simulation studio in new computer, the new component is show in the tree of components, no problem until then, but inmediatly when I try move the new component of tree to space work of simulation studio or I do double click under Type the Trnsys is closes.Really I dont know what happen...I can understand that the new component does not work, but which trnsys closes automatically?in all my pc, trnsys is with license.
i have three question.1. What I can do?2. Does It creates some link between the computer and my pc when is develope the proforma, export to fortran, compile and build ".dll"?3. How i can limit the copy of my new component to a certain number of pc with the userID? or What I can do to that my new component be of free copy?
thanks all
Oswaldo.
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com