Ayman, All TRNSYS types have initial values. The initial values are set by the user and as the driving forces of the system begin to change (ambient temperature, solar radiation, occupancy, etc) start to change then TRNSYS beings to iterate. In high-mass models (such as buildings and thermal storage tanks) the initial values have an important impact on their behavior as the simulation starts going. Iterating more in the first hour isn't going to change anything; the models still start out with those initial values and none of the driving forces have changed yet. If you are concerned about the impact of initial values then the best approach may be to run your simulation for two simulation years and only take the results from the second year. Best, David On 8/3/2011 13:02, Ayman Sarwa wrote:
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 22 North Carroll Street - suite 370 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com |