[TRNSYS-users] Type 56 Thermal Mass



It seems like Type 56 isn't taking into account the concrete floor I have in a space I'm modeling.  What I have is 
I built a 1D finite difference model and wanted to see if my model agreed with TRNSYS.  The problem is that I see a thermal lag and attenuation in the air temperature in my model, while in TRNSYS, the air temperature experiences no lag and varies wildly as it follows the ambient temperature.  It's only when I increase the airnode capacitance to around what my floor capacitance is (7500 kJ/K) that I see good agreement between my model and TRNSYS. 

Why do I have increase this airnode capacitance and is this reasonable?  Thanks so much for any help or insight.

--
Devin M. Rohan, LEED Green Associate
Purdue University
Civil/Architectural Engineering