[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] Visual Fortran run-time error (severe 601)
Marie-Claude,
Try running a search on your computer for a file with either the name
"T15.tmp" or "T89.tmp" and if you find one, delete it. At one point when
processing an *.epw file, both Type89 and type15 open a file called
either T15.tmp or T89.tmp, they write something to it, they read it back
in, then close (and supposedly delete) the temporary file. I can imagine
that if a simulation were to crash in between the time that the file
were created and deleted, it might get left behind. Normally that
shouldn't cause a problem but perhaps it is in your case.
Best,
David
On 5/5/2011 08:44, Marie-Claude Hamelin wrote:
Hi,
I had a functional project with Type89 weather data reading component
and Type16g radiation processor. I had to change those two types for
15-3 because I needed to use a EPW file. Now I get a Visual Fortran
run-time error (severe 601 : file already exists).
There was a similar post on this in 2010 :
https://mailman.cae.wisc.edu/pipermail/trnsys-users/2010/006404.html.
However, I'm using EPW files downloaded directly from DOE's website
(http://apps1.eere.energy.gov/buildings/energyplus/cfm/weather_data3.cfm/region=4_north_and_central_america_wmo_region_4/country=3_canada/cname=CANADA).
I have tried with different files, saved the files in my project
directory, but nothing seems to work.
Has anyone else encountered this kind of issue? Thank you in advance,
Marie-Claude Hamelin
M.A.Sc. Candidate, Building Engineering
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://mailman.cae.wisc.edu/listinfo/trnsys-users
--
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI 53703 USA
P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com
http://www.tess-inc.com
http://www.trnsys.com