Dear TRNSYS users (and developers),
With TRNSYS 17, Type 15-6 !
generate the following error when trying to start a simulation between hours 1024 to 4095, with a small time step (eg 0.1 or 0.15 hour):
"Message : Unable to correctly read from the supplied data file - please check the file an re-run the simulation."
Have you ever got the same error in this configuration?
I also observed a mistake in the code of Type15 when calculating maximum and minimum of monthly avarage temperatures:
The code is as follows :
! Calculate the max and min monthly average
j_min=1
j_max=1
Do j=2,12
If (month_ave_T(j) > month_ave_T(j-1)) j_max=j
&n!
bsp; If (month_ave_T(j) < mon
th_ave_T(j-1)) j_min=j
EndDo
With this code, in the Nothern hemisphere, January can't be the coldest month even if it is. The coldest month will generally be December that is colder that November. I think the code should be:
! Calculate the max and min monthly average
j_min=1
j_max=1
Do j=2,12
If (month_ave_T(j) > month_ave_T(
j_max)) j_max=j
If (month_ave_T(j) < month_ave_T(
j_min)) j_min=j
&n!
bsp; EndDo
Regards,
--
Samuel Hennaut
Chercheur - Doctorant
Université de Liège
Département Sciences et Gestion de l'Environnement
Equipe BEMS - Building Energy Monitoring and Simulation
185, Avenue de Longwy
B-6700 ARLON Tel: 32-(0)63-230 948
Fax: 32-(0)63 230 800
email: shennaut@ulg.ac.be
WEB: http://www.dsge-arlon.ulg.ac.be/bems