[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] floor heating temperature set-point value



Dear all,
 
  I designed a floor heating ( heating is only floor heating ) temperature PID control system. The set-point value is 19 C when  unoccupied, 21C when occupied. But there is a problem: it needs about 2 hours from 19C to 21C, BUT it needs about 7 hours from 21C to 19C. Attached is the figure.
 
 Please tell me why it can result in this situation? and how to deal with it?
 
Many thanks!
 
br.
 
wang
 


 
2010/12/3 <trnsys-users-request@cae.wisc.edu>
Send TRNSYS-users mailing list submissions to
       trnsys-users@cae.wisc.edu

To subscribe or unsubscribe via the World Wide Web, visit
       https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
or, via email, send a message with subject or body 'help' to
       trnsys-users-request@cae.wisc.edu

You can reach the person managing the list at
       trnsys-users-owner@cae.wisc.edu

When replying, please edit your Subject line so it is more specific
than "Re: Contents of TRNSYS-users digest..."

Today's Topics:

  1. not linked into trndll.dll (Bashar Termanini)
  2. Re: not linked into trndll.dll (Matt Duffy)
  3. Re: not linked into trndll.dll (David BRADLEY)
  4. Re: HELP TRNSYS 16 (David BRADLEY)


---------- 已转发邮件 ----------
From: "Bashar Termanini" <bashartermanini@gmail.com>
To: <trnsys-users@cae.wisc.edu>
Date: Fri, 3 Dec 2010 16:19:27 +0200
Subject: [TRNSYS-users] not linked into trndll.dll
Hi,

When I try to use my new component I get this error
"A TYPE was called in the TRNSYS input file but was either not linked into
trndll.dll or was not found in an external dll. A dummy subroutine was
called in its place. Please link the TYPE or remove it from the input file"
Any help?

Thanks




---------- 已转发邮件 ----------
From: "Matt Duffy" <duffy@tess-inc.com>
To: "Bashar Termanini" <bashartermanini@gmail.com>, trnsys-users@cae.wisc.edu
Date: Fri, 3 Dec 2010 08:30:41 -0600 (CST)
Subject: Re: [TRNSYS-users] not linked into trndll.dll
Please make sure that the DLL that you compiled for your new component is
placed in the appropriate directory (.\Userlib\ReleaseDLLs).

Best regards,

Matt Duffy



----- Original Message -----
From: "Bashar Termanini" <bashartermanini@gmail.com>
Sent: Fri, December 3, 2010 8:19
Subject:[TRNSYS-users] not linked into trndll.dll

Hi,

When I try to use my new component I get this error
"A TYPE was called in the TRNSYS input file but was either not linked into
trndll.dll or was not found in an external dll. A dummy subroutine was
called in its place. Please link the TYPE or remove it from the input file"
Any help?

Thanks

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

----- End of original message -----




---------- 已转发邮件 ----------
From: David BRADLEY <d.bradley@tess-inc.com>
To: Bashar Termanini <bashartermanini@gmail.com>
Date: Fri, 03 Dec 2010 09:47:17 -0600
Subject: Re: [TRNSYS-users] not linked into trndll.dll
Bashar,
Also please make sure that you have the following line in your source code:

!DEC$ATTRIBUTES DLLEXPORT :: TYPExxx

where "xxx" is replaced by your Type number. If you are writing Type201, the line would be

!DEC$ATTRIBUTES DLLEXPORT :: TYPE201

Best,
David



On 12/3/2010 08:19, Bashar Termanini wrote:
Hi,

When I try to use my new component I get this error
"A TYPE was called in the TRNSYS input file but was either not linked into
trndll.dll or was not found in an external dll. A dummy subroutine was
called in its place. Please link the TYPE or remove it from the input file"
Any help?

Thanks

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users


--
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com




---------- 已转发邮件 ----------
From: David BRADLEY <d.bradley@tess-inc.com>
To: david.irusta@idom.com
Date: Fri, 03 Dec 2010 10:36:58 -0600
Subject: Re: [TRNSYS-users] HELP TRNSYS 16
David

-How do you Know if the horizontal wall is floor o ceiling?
The TRNSYS 16 building model was non-geometric; when you define a horizontal surface, the only thing that indicates whether it is a floor or a ceiling is the condition that you impose on the opposite side of the surface.
-Creating a Multizone Building,
        when you have to decide the outputs,how can you select a surface(to choose for example TOFL) instead of a Thermal zone?
there are a number of radio buttons across the middle of the window. You still select a zone but then you switch to "surface outputs" and you will see the available NTYPEs for the surfaces in that zone.
        how can you do a multistorey building??
The ceiling of one zone is set as wall type "ADJACENT" and you indicate the name of the zone above whose floor is the same as that ceiling.
I´m interested in create a model about TABS (thermal active building system) which includes active layers
-where can I find examples or tutorials with TRNSYS 16?
I believe that some of the feedback controller examples (..trnsys16\Examples\...) show how to use the active layers.

Best,
 David

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users


Attachment: fig.1.png