Re: [TRNSYS-users] integrate external systems in the type 56



Hi Pablo,

 

You are right, you have to create new inputs. It is very easy to do in TRNBuild (right-click on the building and choos “Edit building”) :

Go to the heating type manager (Typemanager/Heating). Under “Heating Power” choose “limited”. Then click on the green (Trnsys17) or blue (Trnsys16) arrow to create the variable (choose “Input”). Save everything.

 

Back in the project window, right-click on the building again and choos “Update Building Variable list”. Now the new variable appears.

 

Good luck,

 

Werner

 

De : Pablo Díaz Núñez [mailto:p.diazn87@gmail.com]
Envoyé : mercredi 10 novembre 2010 11:50
À : trnsys-users@cae.wisc.edu
Objet : [TRNSYS-users] integrate external systems in the type 56

 

Dear transys-users.

 

I want to integrate a heating system with external equipment in type 56, maybe with radiators or a heating floor. I started using trnsys a month ago and I still don't know how to connect the external equipment to the type 56, I mean, how "to tell" the type 56 that the heat emmited from de radiator is the energy transfered to a zone.

 

I think I have to create some new inputs for the temperature rate control, heat power, etc but I'm not very sure...

 

Thanks in advance,

Pablo.