Hi Pablo, You are right, you have to create new inputs. It is very easy to
do in TRNBuild (right-click on the building and choos “Edit building”) : Go to the heating type manager (Typemanager/Heating). Under “Heating
Power” choose “limited”. Then click on the green (Trnsys17) or blue (Trnsys16)
arrow to create the variable (choose “Input”). Save everything. Back in the project window, right-click on the building again and
choos “Update Building Variable list”. Now the new variable appears. Good luck, Werner De : Pablo Díaz Núñez
[mailto:p.diazn87@gmail.com] Dear transys-users. I want to integrate a heating system with external equipment
in type 56, maybe with radiators or a heating floor. I started using trnsys a
month ago and I still don't know how to connect the external equipment to the
type 56, I mean, how "to tell" the type 56 that the heat emmited from
de radiator is the energy transfered to a zone. I think I have to create some new inputs for the temperature
rate control, heat power, etc but I'm not very sure... Thanks in advance, Pablo. |