[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 567-4 (BIPV) PV efficiency file



Mesude,
  I think you want to use one Type567-2 instead. This mode of Type567 takes the efficiency as an input and not from a data file. Save the efficiency values from your Excel file as a tab-delimited or comma delimited text file. Then use a Type9 (data reader) to read the file during your TRNSYS simulation. The output of Type9 will be the efficiency input to Type567.
Best,
 David


On 10/26/2010 21:44, mesude bayrakci wrote:
Hello,

I used Type 567-4 (BIPV) so I need a external efficiency file.  There is only two solar values and some cell temperature values in The Sample_efficienc.dat file.

I want to calculated cell temperature and efficiency for every  time step during the year. I am attaching my excel file which shows my values. 

How can I use these values or excel file?

Thank you.
_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
22 North Carroll Street - suite 370
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com