Re: [TRNSYS-users] Changing properties of air in a single room?



<In particular we are looking at a box type shape that we could apply
different temperatures to the various walls as they would border different
spaces. >

The Type 531 rectangular storage tank from TESS can do exactly as you
describe.  The user can specify different temperatures on the top and
bottom, plus the temperature on the sides for each node going up the tank.

Jeff