Dear Jeff Thornton Many thanks for your swift reply. Unfortunately, I did your recommended instruction but still the logic unit is not highlighted. As attached the "tmf" file is attached. I was wondering if you could give me your advice to tackle it. Many thanks for your time Regards Mehdi -----Original Message----- From: Jeff Thornton [mailto:thornton@tess-inc.com] Sent: 10 September 2010 04:00 To: Mehdi Shahrestani; trnsys-users@cae.wisc.edu Subject: Re: [TRNSYS-users] Problem in make a link between data file and newcomponent <The data file is linked into the new component and the response is quite well. But, the problem is in performa, the line related to logic unit (parameter for link data file and the component) is not highlighted and is not getting number automatically. Where as in standard components of Trnsys the logic unit line is highlighted and the number is automatically assigned.> When the proforma was created, the user did not associate the logical unit parameter with the external file. Open the proforma in edit mode, go to the 'file' tab and choose the correct parameter in the 'parameter' drop down box. Save the proforma and then use the edit/replace feature in your project to get the new version into your project. Jeff Jeff Thornton President - TESS, LLC 22 North Carroll Street - Suite 370 Madison WI 53703 USA Phone: 608-274-2577 Fax: 608-278-1475 E-mail: thornton@tess-inc.com Web: www.tess-inc.com
Attachment:
Type236.tmf
Description: Binary data