[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] windows in Trnsys



Dear Mr. Beuckelaer!
 
Type35a/b (Windows) could be used for a "manual" window; the ratio of energy transmittance must be supplied as an input.
 
When You create a TRNSYS-glazing in window5 You HAVE TO CHOOSES A FIX frame to avoid a TRNSYS-error. TRNSYS ignores this fixed frame.
Please refer to: http://www.trnsys.com/FreeDownloads/WindowTutorial.pdf
 
With best regards,
    Matthias Kersken
 

---

 

Dipl.-Ing. Matthias Kersken
Wissenschaftlicher Mitarbeiter / Abteilung Energiesysteme

Fraunhofer-Institut für Bauphysik
Institutsteil Holzkirchen

Fraunhoferstraße 10
83626 Valley

eMail: Matthias.Kersken@ibp.fraunhofer.de
Telefon 08024 / 643-204
Telefax 08024 / 643-366
www.ibp.fraunhofer.de

Dipl.-Ing. Matthias Kersken
Research Associate / Department Energy Systems

Fraunhofer Institute for Building Physics
Branch Holzkirchen

Fraunhoferstraße 10
D-83626 Valley

eMail: Matthias.Kersken@ibp.fraunhofer.de
Phone +49 8024 / 643-204
Fax +49 8024 / 643-366
www.ibp.fraunhofer.de

 

 

 

 

 

 

 

 

 

 

 

 

 

---

 


Von: Joke De Beuckelaer [mailto:joke.d@vkgroup.be]
Gesendet: Montag, 5. Juli 2010 10:28
An: trnsys-users@cae.wisc.edu
Betreff: [TRNSYS-users] windows in Trnsys

Dear Trnsys-users,

 

I?ve some question concerning windows in Trnsys. When you want to implement a window (with a known U-value and g-value) but there is no corresponding window in the library, can you somewhere adapt the U-value and g-value?

I know you can use window5 to make a new window in your library, but sometimes I don?t know the layers of my window but just the U-value en g-value. Can you adapt perhaps the values of the additional heat resistance of an external shading device to achieve the wanted value? Or adapt the U-value of the profile?

 

When you do use window5: you have to introduce a profile too.  But in trnsys, you select the created window under ?Glazing?. Do you then still have to introduce the U-value of the profile in Trnsys or ? ?

 

Thanks in advance,

  Joke De Beuckelaer   