Hi David,
My proforma file lists
the 13 outputs, that the code contains..
Is this maybe some sort
of compiler problem?
Thanks,
Marius
Von: David Bradley [mailto:bradley@tess-inc.com]
Gesendet: Freitag, 30. April 2010
18:19
An: Marius Müller
Cc: trnsys-users@cae.wisc.edu
>> "trnsys-users@cae.wisc.edu"
Betreff: Re: [TRNSYS-users] output
number beyond the allocated outputs
Marius,
I think the problem might actually be in your input file and not in the
component itself. The error mentions that an input is referencing an output
beyond the range of outputs declared. Your Type has 13 outputs and looks like
it is coded correctly. However, if the proforma for the component lists 14
outputs (for example) and you connect that output up to the input of another
component, you'll get the error that you mention.
Best,
David
-----
Original Message -----
From: "Marius
Müller" <m.mueller@solitem.de>
Sent: Thu, April
29, 2010 6:19
Subject:
[TRNSYS-users] output number beyond the allocated outputs
Hello everyone,
I have a problem that trnsys delivers an error when I have
too many outputs. Or something like that:
The listed input referenced an output number beyond the allocated outputs
for the connected type.
The error was already mentioned by someone, but the answer
is not working.
Maybe someone can help,
Thanks,
Marius