Re: [TRNSYS-users] output number beyond the allocated outputs



Marius,
 I think the problem might actually be in your input file and not in the component itself. The error mentions that an input is referencing an output beyond the range of outputs declared. Your Type has 13 outputs and looks like it is coded correctly. However, if the proforma for the component lists 14 outputs (for example) and you connect that output up to the input of another component, you'll get the error that you mention.
Best,
 David

----- Original Message -----
From: "Marius Müller" <m.mueller@solitem.de>
Sent: Thu, April 29, 2010 6:19
Subject: [TRNSYS-users] output number beyond the allocated outputs

Hello everyone,

I have a problem that trnsys delivers an error when I have too many outputs. Or something like that:

The listed input referenced an output number beyond the allocated outputs 
for the connected type.

 

The error was already mentioned by someone, but the answer is not working.

Maybe someone can help,

 

Thanks,

Marius