Dear Bashar Termanini,

In TRNSYS 16, you are only allowed up to 5 online plotters in a simulation. As you mentioned, you can most definitely have more than 5 in your *.tpf project, but the TRNEXE will only 'plot' 5 of them. The simplest way to deal with this is to set the 9th parameter of your online plotter, "Shut off Online w/o removing", to "-1". This will keep this particular instance of Type65 in your project, but it wil not display the results dynamically as you simulate.

Best regards,

Matt Duffy


----- Original Message -----
From: "Bashar Termanini" <bashartermanini@gmail.com>
Sent: Thu, April 22, 2010 3:21
Subject: [TRNSYS-users] Type 65c

Hello,
 
I ues 9 Type65c (Online Ploter with file) in my projec.  when I run the project I get 9 output file, but it plotes only 5 diagram.
how can I solve this problem?
 