[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 24 - Integration Period



Edward,
I'm not sure I follow your question. In one case, are you setting the integration period to -12 to indicate that you want a 12 month integration period? I have never tried that and am not sure if it is a valid value; I have only ever used a -1 to indicate monthly integration. If you use a -1 and an 8760 you should get the same integral for the entire year. I'll check what happens when you set a -12 and see if it should be prevented.
Best,
David


Edward Halawa wrote:
Dear All,

Shouldn't the integration period (PAR(1) in TYPE 24) of 8760 hrs equivalent to -12 hrs (i.e. one year ?) I got different answers. (I'm running TRNSYS 16 studio project). When I run the TRNSYS 15 deck file the results are identical.

ehalawa


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users




--
***********************************************************************
Thermal Energy System Specialists (TESS), LLC David BRADLEY 22 N. Carroll Street - Suite 370 Partner Madison, WI 53703 USA P: +1.608.274.2577 F: +1.608.278.1475 E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com

***********************************************************************