Dear Vázquez, The reason for this could be an inconsistence between the type and the TRNSYS kernel you use. If the type is compiled in debug mode and the default kernel of TRNSYS is in release mode there could be some troubles. Try to copy the TRNDll.dll from ..\Trnsys16_1\Compilers\Cvf66\TRNDll\Debug to ..\Trnsys16_1\Exe (this is the calculation kernel in debug mode). You have to replace the existing TRNDll.dll in this directory. I hope it helps. Best regards, Hermann. _______________________________________________________________ DI Dr. mont. Hermann Schranzhofer Institut fuer Waermetechnik / Institute of Thermal Engineering TU Graz / Graz University of Technology Inffeldgasse 25 / B, A-8010 Graz Tel.: +43 316 873 7314 mobil: +43 664 60 873 7314 Fax : +43 316 873 7305 http://www.iwt.tugraz.at/ _______________________________________________________________ ________________________________________ Von: Mavi Cambronero Vázquez [mailto:maviqnk@gmail.com] Gesendet: Dienstag, 13. April 2010 09:51 An: trnsys-users@cae.wisc.edu Betreff: [TRNSYS-users] Fatal error: Unable to find fluid data file Hi everybody! I have a problem with my trnsys... I´m trying to simulate a project but a fatal error appears "unable to find fluid data". I have all the files in the same folder and the instalation of the types is ok. The best is that other people are able to run the project and work without any problem. I suspect it´s a problem with the fortran code, maybe the configuration of my computer, of my trnsys or I don´t know. If someone had the same problem or someone know what happen, please let me know because I don´t understand why this is so. Thank you!! Best regards Mª Victoria Cambronero Vázquez