[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[TRNSYS-users] Type 71 flow rate & IAM
A couple more Type71 questions.
1. The SPF test report for my evacuated tube collector gives the 'Flow rate during test' as 119l/h. I'm not sure how to convert this into the "Flow rate at test conditions" in kg/hr.m2 required by the model (ie per unit area), as the report doesn't detail what the area is where they measure this flow rate?
2. In the Type71 example, parameters 10/11 for the no. of IAM angles are given as 5. The associated IAMData.dat file in the Examples directory has 7 angles. I assume that 0 and 90 do not count? In my SPF report I have 10 angles (0, 10, 20, etc) for which I have created an equivalent .dat file. Should I hence set the parameters 10/11 to 8, indicating 8 angles plus 0 and 90 ?
3. I'm a bit confused about Parameter 9, the "Logical unit of file containing biaxial IAM data", what does this represent ?
many thanks,
Ben