Re: [TRNSYS-users] wiring node temperature outputs of type 60 - (TRNSYS16-01-003)



Thanks for your answer,

 

I actually wanted to set 20 nodes in the tank and had set correctly  the derivatives : the max number of outputs in the proforma was locked to 13 . Either I have to modify the standard proforma max to 50 as said in the documentation or use equations for the desired output (what i did).

It looks like a minor error in proforma type60d in the TRNSYS Studio distribution, doesn’t it?

 

Problem is now solved in my application.

 

Thanks

 

David

 

 

De : David Bradley [mailto:bradley@tess-inc.com]
Envoyé : vendredi 6 février 2009 05:51
À : David Chèze
Cc : trnsys-users@engr.wisc.edu
Objet : Re: [TRNSYS-users] wiring node temperature outputs of type 60 - (TRNSYS16-01-003)

 

David,
  The node temperatures are the last set of outputs of Type60. In the proforma, make sure that you have answered the question about how many nodes there are both in the "outputs" tab and in the "derivatives" tab.
Kind regards,
 David


David Chèze wrote:

Hello,

 

Is there another way than equations to wire node temperature outputs of type 60 in the studio : these outputs are not visible when wiring the proformas.

 

Thanks for your help.

 

David Chèze

CLIPSOL / R&D

 

 


 
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
  



-- 
***********************************************************************
Thermal Energy System Specialists (TESS), LLC 
David BRADLEY                      22 N. Carroll Street - Suite 370 
Partner                            Madison, WI 53703 
                                   USA
P: +1.608.274.2577 
F: +1.608.278.1475
E-mail: bradley@tess-inc.com 
Web Pages:  http://www.tess-inc.com    and      http://www.trnsys.com
 
***********************************************************************