Kiki,
 The Type67 data file surface angles for which obstruction heights are provided correspond to absolute azimuths. They are not specified relative to the azimuth of the opening. If you want to turn your building, you need apply the same turn in the Type67 data file. The "turn" equation only turns the building itself, not its surroundings.
Kind regards,
 David


kiki siouna wrote:
Thank you.
I have one more question. In my simulation for the shading of the building from the surrounding buildings i used type 67. Now i want to turn the building, so i change the azimuth of surfaces in the equation 'turn'. With this, i turn only the simulated building or the hole system( simulated building and surroundings).
Thank you for your help.


_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***********************************************************************