Chun Kwong, Yes, the Type will be called one last time with INFO(13)>0 even if there wasn't convergence during the time step. That step should really be called "end of time step" instead of "post convergence" Kind regards, David a8304506@graduate.hku.hk wrote: Hello, Trnsys users. I am developing a component which needs to store some parameter values at the end of each time step (not for each iteration). In the standard Fortran source code, there is a statement "If (INFO(13)>0) Then...". If convergence fails in a particular timestep, will INFO(13) still be greater than zero? If not, how can I save the parameter values in this case? Please advise. Thank you! Best Regards LEE, Chun Kwong Research assistant Division of Building Science and Technology City University of Hong Kong -- *********************************************************************** Thermal Energy System Specialists (TESS), LLC David BRADLEY 22 N. Carroll Street - Suite 370 Partner Madison, WI 53703 USA P: +1.608.274.2577 F: +1.608.278.1475 E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com *********************************************************************** |