Chun Kwong,
 Yes, the Type will be called one last time with INFO(13)>0 even if there wasn't convergence during the time step. That step should really be called "end of time step" instead of "post convergence"
Kind regards,
 David


a8304506@graduate.hku.hk wrote:
Hello, Trnsys users.

I am developing a component which needs to store some parameter values at the
end of each time step (not for each iteration).  In the standard Fortran source
code, there is a statement "If (INFO(13)>0) Then...".  If convergence fails in
a particular timestep, will INFO(13) still be greater than zero?  If not, how
can I save the parameter values in this case?  Please advise.  Thank you!

Best Regards
LEE, Chun Kwong
Research assistant
Division of Building Science and Technology
City University of Hong Kong




  

_______________________________________________ TRNSYS-users mailing list TRNSYS-users@cae.wisc.edu https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users

-- 
***********************************************************************