Dear Benoit,

I had a similar error with TrnOpt. When you have errors with Trnopt, try to search in the files generated by TRnOpt, there are more precise informations in it.

I had to change the regional informations of Windows, and change the decimal separator, which is a comma for France. I think TrnOpt needs a dot.

Hope this helps.
Regards,


Dear TRNSYS - TRNOpt Users,
I have installed the TRNOpt programme that work with GenOpt 2.1. But I can't get an optimization working! GenOpt keeps returning the following error:
    genopt.lang.OptimizerException:
    Error in searching for the objective function value:
      The objective function value could not be found.
      - Check the optimization ini file for
        the prober value of SimOutputFile.
      - Check the SimOutputFile for the prober
        structure.
      - Check the optimization configuration file for
        the prober value of the objective function delimiter.
        Objective function delimiter is 'Variable Value 001 ='.

I have tried with different TRNSYS files, including the example provided with TRNOpt. The same error appears all the time. Has anyone encountered a similar error? Thanks for your help! Best Regards,
Benoît
----
Benoît Andlauer
Research Engineer - Ph.D Student
Center for Energy and Processes
60, bd St Michel - F-75272 Paris Cedex 06
Tel: +33 1 40 51 94 19
Fax: +33 1 40 51 94 25
benoit.andlauer@ensmp.fr <mailto:benoit.andlauer@ensmp.fr>
------------------------------------------------------------------------

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@cae.wisc.edu
https://www-old.cae.wisc.edu/mailman/listinfo/trnsys-users
--
Thibaut Vitte
thibaut.vitte@h3c-energies.fr

H3C Energies
Services et Conseils en énergie
35 Ch. du vieux Chêne
38 240 Meylan

Tel. 04 76 41 88 66
Fax. 04 76 41 28 94
Mob. 06 23 42 05 07

www.h3c-energies.fr