----- Original Message -----
Sent: Thursday, July 24, 2008 2:12
PM
Subject: Re: [TRNSYS-users] glazing
library,existance of the glazings specified
Dear
Romain,
Transsolar compiled the Germain window library (w4-lib.dat) based
on manufacturer data. I had a look at the library
but
I couldn't find a glazing with your specification.
Which library did you use (other than German)? What is the
WinID number?
Thanks,
Marion
-----Ursprüngliche Nachricht-----
Von:
Romain GOURDON [mailto:romain.gourdon@gmail.com]
Gesendet:
Donnerstag, 24. Juli 2008 10:44
An: trnsys-users@engr.wisc.edu
Betreff:
[TRNSYS-users] glazing library, existance of the glazings
specified
Hello,
I am currently trying to do thermal balances of
different types of windows using the glazing library of TRNSYS.
The
"best" triple glazing I found is the "Saint Gobain CLIMATOP K", Ug=0.52 and
g=0.585. This solar factor is better than any other type of triple and even
double glazing! I never found any technical nor comercial document that
confirms such a performance. Was the glazing system just simulated by
software or is it real and "buyable"?
Thanks in advance for your
help.
Best regards
Romain
GOURDON
Enertech