[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] how not to get output list file(*.lst)



Sato,
I think that either I misunderstood the use of the NOLIST statement or else it has changed! It seems that using the NOLIST statement will prevent TRNSYS from writing the contents of the input file to the list file but that the warnings, notices, and errors will still always be written. Could you please send me your *.lst file so that I can get an idea of what information is being written there?
Kind regards,
David


佐藤 昭一郎 wrote:
Dear David

Thanks for the swift response.
I used "NOLIST",but I could not suppress the list file.
Do I misuse "NOLIST"card?

Below is a part of deck file.
Thanks in advance.

Sato

*******************************************************************************
*** Units *******************************************************************************

*******************************************************************************
*** Control cards
*******************************************************************************
* START, STOP and STEP
CONSTANTS 3
START=1
STOP=24
STEP=1
* User defined CONSTANTS
SIMULATION 	 START	 STOP	 STEP	! Start time	End time	Time step
TOLERANCES 0.001 0.0000001			! Integration	 Convergence
LIMITS 10000 10000 0				! Max iterations	Max warnings	Trace limit
DFQ 1					! TRNSYS numerical integration solver method
WIDTH 80				! TRNSYS output file width, number of characters
NOLIST 					! NOLIST statement
MAP 					! MAP statement
SOLVER 0 1 1				! Solver statement	Minimum relaxation factor	Maximum relaxation factor
NAN_CHECK 1				! Nan DEBUG statement
OVERWRITE_CHECK 1			! Overwrite DEBUG statement
TIME_REPORT 1			! enable time report statement
EQSOLVER 0				! EQUATION SOLVER statement
-----Original Message-----
From: David Bradley [mailto:bradley@tess-inc.com] Sent: Friday, June 20, 2008 6:58 PM
To: 佐藤 昭一郎
Cc: trnsys-users@engr.wisc.edu
Subject: Re: [TRNSYS-users] how not to get output list file(*.lst)

You can suppress the list file by switching the "LIST CARD" field in the Studio's component control cards from "LIST" to "NOLIST." However, before you suppress the list file, I would recommend that you make a run allowing TRNSYS to write the list file, then look at it and make sure that there aren't a lot of warnings being written there during your simulation.
Kind regards,
 David


佐藤 昭一郎 wrote:
Dear all

I use TRNSYS 16.1.
I have trouble about getting output a big size list file(*.lst) Please tell me how not to get output list file(*.lst).

Thanks in advance
yours
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users




--
***********************************************************************
Thermal Energy System Specialists (TESS), LLC David BRADLEY 2916 Marketplace Drive - Suite 104 Partner Madison, WI 53719 USA
P: +1.608.274.2577
F: +1.608.278.1475
E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com

***********************************************************************


--
***********************************************************************
Thermal Energy System Specialists (TESS), LLC David BRADLEY 2916 Marketplace Drive - Suite 104 Partner Madison, WI 53719 USA P: +1.608.274.2577 F: +1.608.278.1475 E-mail: bradley@tess-inc.com Web Pages: http://www.tess-inc.com and http://www.trnsys.com

***********************************************************************