[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] TESS libraries problem
Filippo,
You should not need to add the TESS Library components to the
Fortran workspace or rebuild the TRNDll.dll in order to use those
components. If the TESS Libraries are installed in the proper location,
you should find a series of DLLs in the ..\Trnsys16\UserLib\ directory.
Those DLLs are loaded by TRNSYS when you run a simulation. The notices
that you are receiving indicate that the components you are trying to use
are not being found anywhere. Please check in the ..\Trnsys16\UserLib
directory and make sure that there are no subdirectories called
\ReleaseDLLs or \DebugDLLs. If there are, then move the contents of
..\Trnsys16\UserLib\ReleaseDLLs\***.dll to ..\Trnsys16\UserLib\***.dll,
and try to run the simulation again.
Kind regards,
David
At 02:50 3/3/2008, Filippo Busato wrote:
Dear All,
here at the university of Padova (Department of Management and
Engineering) we have a version of TRNSYS 16.00.0038, and we got the cd of
TESS libraries for geothermal, version 2.
I tried to use those types (e.g. horizontal buried exchanger), after
adding the new types to theworkspace and having properly rebuilt Trnsys
in the Fortran environment.
The simulation doesnt' start and the following error messages are
shown:
i.
"TESSLibrary_PVThermalModels_ReleaseVersion_NotForDistribution.dll"
was found but did not contain any components from the input
file.
ii. "TYPE 154.dll" was found but did not contain any components
from the input file.
iii. "Type152.dll" was found but did not contain any components
from the input file.
iv. "Type153.dll" was found but did not contain any components
from the input file.
v. "Type154.dll" was found but did not contain any components
from the input file.
vi. TRNSYS Message 199 : TRNSYS found at least one user
DLL in the UserLib directory. (Note: Only DLL's including Types that are
used in the simulation are loaded) Reported information : 0
user DLLs were loaded after searching in
"C:\Programmi\Trnsys16\UserLib"
Can you please help me to run those types properly?.
Thanks a lot
Filippo
--
------------------------------------------------------------------------------------------
Filippo Busato - Ph.D.
ingegnere
Università degli Studi di Padova
Dipartimento di Tecnica e Gestione dei sistemi industriali
Str.lla S.Nicola, 3 - 36100 Vicenza (VI)
mailto: busato@gest.unipd.it
homepage:
http://www.gest.unipd.it/~busato
skype: foucault76
tel: +39 0444 998846
fax: +39 0444 998884
mob: +39 347 1207174
------------------------------------------------------------------------------------------
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David
BRADLEY
2916 Marketplace Drive - Suite 104
Partner
Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:
http://www.tess-inc.com
and
http://www.trnsys.com
"Providing software solutions for today's energy engineering
projects"
****************************************************************************************