[TRNSYS-users] problem with type 109 user format



Dear All,

I am using type 109 in mode 1 to read my weather data for Cardiff. The data I am using is in 5 min
intervals (from local weather station, measurements for year 2007). The problem is that I get
warnings in the List file saying that the data includes isnolation values >0 W/m2at times when the
sun is down (and then the software sets this values to 0). I cannot find the mistake in my *.109.
Can someone take a look in the attached file and help me? It will be much appreciated...

Best Regards

Eleni Ampatzi
PhD Student, WSA, Cardiff University

Attachment: WeatherDataReading.TPF
Description: Binary data

Attachment: Metsite_year2007_weatherdata.109