[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [TRNSYS-users] Micro Processor
Arnaud,
In order to keep the size of TRNDll.dll smaller, there are
sometimes limits in the Fortran code itself. If you want to use more than
100 parameters for Type40, you need to modify the line:
PARAMETER
(NPMAX=100,...
in the fortran code and recompile the TRNDll.dll. If you aren't
able to do that yourself, let me know and I can make you a new dll.
Cheers,
David
At 07:18 7/5/2007, Arnaud Vandendriesche wrote:
Hello TRNsys users,
I use the type 40 in my project. When I run my project, I have a message
:
*** Fatal Error at time :
4000.000000
Generated by Unit
: 76
Generated by Type
: 40
Message : The maximum allowable number of
PARAMETERS for this Type was exceeded.
But I respect the limit for NCT, NMODE,...
I join the proforma.
Thank you for your help.
Arnaud Vandendriesche (student at the Faculté Polytechnique de Mons
Belgium)
Content-Type: application/octet-stream;
name="Premierprocess.tmf"
Content-Disposition: attachment;
filename="Premierprocess.tmf"
X-Attachment-Id: f_f3r7efh2
Content-Type: image/bmp; name="Premierprocess.bmp"
Content-Disposition: attachment;
filename="Premierprocess.bmp"
X-Attachment-Id: f_f3r7fkr6
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users
****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David
BRADLEY
2916 Marketplace Drive - Suite 104
Partner
Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:
http://www.tess-inc.com
and
http://www.trnsys.com
"Providing software solutions for today's energy engineering
projects"
****************************************************************************************