Dear Feng,

I am attaching a simple example that shows how to use Type48 and Type47 for an off-grid system, and also a grid-connected system with inverter. A feature of the example is that the PV-module is using a maximum power tracker at all times.

I would recommend that you take a look at this example, and start from there to make your modifications, for example, replacing the maximum power point tracker with the resistance load. Please make sure that you are running the latest version of TRNSYS (16.01.0003). There was a change in Type194 that may conflict with previous versions of TRNSYS.

Best regards,

Diego



Feng Shao wrote:
Hellow dear TRNSYS experts,
I'm a student working on the simulation of stand alone PV system using TRNSYS16.
The system i want to simulate is combined with: a PV module, a 12V battery, a
regulator(DC/DC converter) and a resistor as load.

The problems: the TYPE48 mode2 and 3 have the additional capabity of charging
the battery from the utility. That's what i don't need in my system. How can i
aviod the effect of grid to the system. i want to keep those to modes because
they have the similar strategy to my regulator.

And why the state of charge which is output from the battery model TYPR47 is
correspond to its parameter "cell energy capacity". Isn't it should be cell
energy capacity*cell number in series*cell number in parallel= battery capacity
?

Finally, is it possible to simulate a simple stand alone PV system with TRNSYS?

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users


--
Diego A. Arias
TRNSYS Coordinator
Solar Energy Laboratory
University of Wisconsin - Madison
1500 Engineering Drive
Madison, WI 53706

Attachment: TRNS-PV.tpf
Description: Binary data