[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Modeling of a urban canyon with Trnsys



Hi Guillaume,

In TRNBuil you can add a window that is not attached to a wall. Open a zone definition window; look that in the pane 'walls' the first option is 'Additional windows'. Just select it, and then go to the button 'Add' under the pane 'Windows'.
Best regards,

Diego

Guillaume Faye wrote:
   Hi,
   I am studying the effect on the urban climate of flat-plate collectors
integrated in the buildings' frontages. To do this study, I am trying to model a urban canyon . My idea is to create two zones with TRNBuild, one
   modeling the canyon street and the other one modeling a building. The
problem is that the street should be open to the upper atmosphere and with TRNBuild I have to define a wall. I have created a window which is entirely
   transparent to solar radiation to do as if there was no window. But I
don't succeed in defining this window as a wall. I mean I am obliged to define a wall and after to add a window to this wall, but the window can't have the same area as the wall. So do you know a way to define a window as
   an entire wall?
   Thank you
Guillaume Faye

P.S.: I would be interested in any other ideas about how to model a urban
   canyon with Trnsys and TRNBuild
------------------------------------------------------------------------

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users


--
Diego A. Arias
TRNSYS Coordinator
Solar Energy Laboratory
University of Wisconsin - Madison
1500 Engineering Drive
Madison, WI 53706