[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 66, Error32 ??



Meriem,

      1- I tested a simple simulation with type 66 b and I got an error message:
Error 32: The end of the input file was found before the End statement was found.
Can someone help me solve this problem?

it turns out to be a problem in Type65. If you look at the "special cards" tab, you will notice that there are three labels required "left axis title," "right axis title," and "plot title" but only one label is specified. Because Type65 appears last in your input file, the END statement is being read as though it were the second label.

      2- Is there a way to test (to know) the contents of the clipboard during the simulation?
I think that will help me know about the inputs of EES.

yes, because the information is on the clipboard, you can just open a text editor and choose the "paste" option - you'll be able to see what is being passed to or from EES.
Cheers,
 David



Découvrez une nouvelle façon d'obtenir des réponses à toutes vos questions ! Profitez des connaissances, des opinions et des expériences des internautes sur Yahoo! Questions/Réponses.
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com