[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type55 in series



Dear Amandine,

There are several options to solve your problem:
1. You can use one Type55 to sum the output during each month (like you are doing now), and then another one in parallel to sum the same output for the entire year. In order to add a line to your summary, you can create a copy of the printer Type25 (this will make sure that you print to the same file). Set the parameters so it prints at the end of the simulation (8760 hour), change the logical unit to the same one that the original Type 25 has, and set parameters 8 and 10 to -1. Finally, send the output from the second Type55 to this instance of Type25.

2. You can use type28. The description of this component says: "Type28 can be conveniently used to generate daily, weekly, monthly or seasonal summaries of information computed in a simulation. Its output can be displayed either in a boxed format or as a table. Type 28 integrates its inputs over the time interval of the summary, performs user specified arithmetic operations on the integrals, and prints the results. This configuration prints results to an external file" Type28 gives you lots of possibilities, but you will have to read the mathematical description in order to use the conventions for the operations.

3. Finally, I think that the easiest solution is to add the 12 lines of your file while you post-process your results in a spreadsheet.
Best regards,

Diego


Amandine LE DENN wrote:
Dear users,
I calculate the sum of an output over a period of 1 month, each month, during one year using Type55. Then, "Printer" Type25 produce a file with monthly datas (12 lines). I would like to calculate the sum of the same output over a period of 1 year, placing a new Type55 in serie, after the first one, doing the sum of 12 monthly values. Do you know:
- how to set the second Type55 parameters?
- how to write a file containing the 12 monthly values _and_ total annual value. I run an hourly simulation of 8760 hr. Thank you for your help, Amandine LE DENN
------------------------------------------------------------------------

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users


--

Diego A. Arias
TRNSYS Coordinator
Solar Energy Laboratory
University of Wisconsin - Madison
1500 Engineering Drive
Madison, WI 53706