[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] Heat exchanger



Dear TRNSYS users,

 

I am looking for a solution to simulate a heat exchanger with fixed value of overall heat transfer coefficient (TYPE 5) in TRNSYS 15. The model must be able to keep the cold-side outlet (T1; see jpg-file) on a given temperature (setpoint) by controlling the flow rate on hot side.

 

I suppose TYPE 650 from TESS component library has a similar control function, but with constant effectivness.

 

Has somebody an idea?

 

Thanks in advance!

 

 

Hans Peter Wirth

ZfS Rationelle Energietechnik GmbH

Verbindungsstr. 19

40723 Hilden

Germany

zfs.energie@t-online.de




Attachment: heat exchanger.jpg