[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type4 - control strategy



Dear Amandine,
  The simplest thing to do is to set the power of the two Type2 auxiliary heaters to zero. Then, no matter what the internal thermostats decide to do, the heaters are unable to increase the temperature of the water in the tank.
Kind regards,
 David


At 10:22 3/29/2006, Amandine LE DENN wrote:
Dear Trnsys users,
 
I would like to use Type4 storage tank with one auxiliary heater, only controlled by a ON/OFF controller (Type2).
However, it seems that the other conditions (temperature conditions inside the tank: Tthermostat < Tset and Tnode < Tset - Tdb) already control the ON/OFF cycle of the auxiliary heater.
What can I do to avoid those two conditions ? If I give the same value to Tdb and Tset , auxiliary heater doesn't work.
I modeled a tank with one node.
 
Thank you for your answers,
 
Amandine LE DENN

INSA Toulouse
Mel: amandine.le-denn@tecsol.fr
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
TECSOL
105 avenue Alfred KASTLER
Tecnosud - B.P 434
66004 PERPIGNAN cedex
FRANCE
Tel: +33(0)4.68.68.16.40
Fax: +33(0)4.68.68.16.41
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com

"Providing software solutions for today's energy engineering projects"
****************************************************************************************