[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] "floor in direct contact with ground"



Christophe,
  Your translation is perfectly fine. Sometimes the effect is called "ground coupling" as well.

  To answer your question, the "standard" method is to define a massless layer with a high thermal resistance underneath your floor and connect it to either ambient temperature or some time varying deep earth ground temperature. You might get such a temperature from the Type77 Kasuda correlation. In some parts of the world, there are maps of equivalent ground temperatures available just for this purpose. Alternatively, there are a number of ground coupling models in the TESS Ground Coupling library that you might use. These are a bit complicated to implement but the idea of them is more physically correct than the equivalent resistance method. In the Ground Coupling Library models, you define a volume of soil underneath and around the floor. That volume of soil is called the "near field" and is broken up into finite elements that normally increase in size as they get farther from the floor edge and bottom. Beyond the near field is a region called the far field, which acts as an infinite thermal source / sink. When using a ground coupling model with Type56, you define a boundary wall for your floor and pass the inside surface temperature of the floor out of Type56 and to the ground coupling model. The ground coupling model solves the 3D finite element conduction problem and calculates the temperature at the outside boundary of the floor. This outside boundary temperature is passed back to Type56 as an input.

  We have had some good success with the model and have been working with the developers of one of the International Energy Agency Tasks to compare this model against an analytical solution and against other models that have been created over the years. The 3D finite element methodology seems to be uniquely flexible and shows quite good comparison with the analytical solution.
Kind regards,
 David



At 05:55 2/17/2006, Enertech wrote:
Dear TRNSYS Users,
 
I would like to model a ?floor in direct contact with ground? (I don?t know the exact traduction for the french term ?plancher sur terre plein?). My goal is to estimate the interest of using the ground thermal capacitance, as a heat storage, in the global thermal capacitance of my building.
 
My first idea was to define a boundary wall with the ground temperature for boundary. But in this case, I don?t use ground capacitance. My new idea is to introduce a layer in my wall (defined as an external wall) composed by 5 m of ground ? Do you think it?s a good way to take ground capacitance into account ?
 
Thanks for your answers,
Christophe.

===========================
ENERTECH
F-26160 FELINES SUR RIMANDOULE
tel-fax : 04 75 90 18 54
Email : sidler@club-internet.fr
Web  : http://sidler.club.fr
================================
_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@engr.wisc.edu
https://www.cae.wisc.edu/mailman/listinfo/trnsys-users

****************************************************************************************
Thermal Energy System Specialists (TESS), LLC
David BRADLEY                           2916 Marketplace Drive - Suite 104
Partner                                        Madison, WI 53719
Phone: (608) 274-2577 USA
Fax: (608) 278-1475
E-mail: bradley@tess-inc.com
Web Pages:  http://www.tess-inc.com     and      http://www.trnsys.com