[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] DLL Library



I have experienced this strange error recently. I was not using Type1316, and I had the same experience: running from the Studio works, running from the command line fails.

The workaround I found is to simply remove TESS_UT_Type1316_v18_0_64.dll from the UserLib\Release directory (renaming it wasn’t enough, even if changing the extension).

Of course, if you use Type1316 in your simulation, that won’t work…

 

Michaël Kummert

Polytechnique Montréal

 

 

From: Misbaudeen Adesanya via TRNSYS-users <trnsys-users@lists.onebuilding.org>
Sent: March 27, 2023 07:42
To: trnsys-users@lists.onebuilding.org
Cc: Misbaudeen Adesanya <misbauadesanya@gmail.com>
Subject: [TRNSYS-users] DLL Library

 

Dear TRNSYS users,

 

I am trying to run a simulation from the command prompt. However, I have encountered this error " The procedure entry point TRNSYSFUNCTIONS_mp_GETGLOBALOUTPUTVALUE could not be located in the dynamic link library "C:/TRNSYS18/UserLib/ReleaseDLLs/TESS_UT_Type1316_v18_0_64.dll". However I have TESS_UT_Type1316_v18_0_64.dll in the folder DebugDLL and ReleaseDLL.

 

I don’t have any problem running the simulation from the simulation interface. 

 

Has anyone come across this problem? How do I solve it?

 

Thank you all.

--

Misbaudeen Aderemi Adesanya

Department of Agricultural Civil Engineering

College of Agricultural & Life Sciences
Kyungpook National University

1370 Sangyuk-dong, Puk-gu
Daegu 702-701, South Korea

대구시 북구 산격동 경북대학교 농업토목공학과

Cell phone: +82-10-5168-7503

                    +234-81-6487-7503