[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] python/trnsys



Hi all

I am using B18

When I change the volume that provides  different results. By default capacitance is 1.2*volume. But when I change, manually, the capacitance value that gives no change. It seems that the capacitance has no effect, whereas in the documentation it is written

In order to simplify the input, default values for all parameters except the volume are provided. The capacitance will be automatically set to a default value of 1.2*volume. However, it is recommended to check the default values carefully and to adjust them if necessary.

De : Maurice Charbit - OZE-ENERGIES
Envoyé : mercredi 17 novembre 2021 14:07
À : trnsys-users@lists.onebuilding.org <trnsys-users@lists.onebuilding.org>
Objet : python/trnsys
 

Hi all,

 

I am using subprocess.call in Python to run trnsys

When trnsys crash, trnsys opens a windows and waits for a manual response. How can I circumvent this issue ?

 

Regards

 

Maurice