[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Question about floor heating



Jihane,

  Yes, typically you use the "wallgain" feature. Each of the surfaces in each of your zones allows you to "insert" energy directly into the surface as would be the case with a layer of electric resistance heating inside a wall or floor.

kind regards,

 David


On 06/15/2022 03:58, jihane ziraoui via TRNSYS-users wrote:
Dear all,

I have a question about floor heating.
I simulated a building with floor heating in TRNBuild using type 56.
Please, if I want to add electric floor heating, is it possible without using the active layer? also, how can I add it?

Your help is much appreciated
Thanks in advance

Best regards.
_______________________
Jihane ZIRAOUI
         Research assistant, Ph. D student 
        +212628145746

Garanti sans virus. www.avast.com

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy System Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com