Lumi,

 I would suggest you send the project and any files needed to run it to your distributor. Trnsys17 is no longer officially supported but they may be able to find time to take a look at the problem. I suspect that the error message is a follow on meaning that the actual error appeared earlier in the input file earlier but the input file was still able to be processed (understood) until it came to the text that is quoted in the reported information section. If you aren't sure who your distributor is, please send me a direct email and I can point you in the right direction.

kind regards,

 David


On 04/13/2022 08:37, Lumi Dumitrascu via TRNSYS-users wrote:

Hello,

 

I am trying to use Type 918 (Multimode dehumidifier) and I get the following fatal error:

 

Fatal Error at time   :         0.000000

    Generated by Unit     : Not applicable or not available

    Generated by Type     : Not applicable or not available

    TRNSYS Message     99 : Bad or missing data on control card. TRNSYS understood a keyword and is looking for additional information for that keyword, but cannot find it. The control card is in "reported information" below.

    Reported information  : ASSIGN "C:\Trnsys17\Tess Models\SampleCatalogData\MultimodeDehumidifier\AirRejection_Normalized.dat"

                                               ASSIGN "C:\Trnsys17\Tess Models\SampleCatalogData\MultimodeDehumidifier\AirRejection_Normalized.dat"                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    

ASSIGN "C:\Trnsys17\Tess Models\SampleCatalogData\MultimodeDehumidifier\AirRejection_Normalized.dat"                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    

  

I would like to mention that there is no example or proforma available in the TRNSYS provided documentation.

 

Any help would be highly appreciated. Thank you!

 

Lumi Dumitrascu                                                                      


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy System Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com