Gokula,

  It is not entirely clear from the screen capture that you sent what the compiling problem might be. If you are using an older version of the Trnsys v17 code look in the file CallProgram.f90 and make sure that the line

 Use ifport , only:createProcess

is commented out. It should have an exclamation point at the start of the line as in:

 !Use ifport , only:createProcess

kind regards,

 David


On 01/09/2022 08:33, SENTHIL KUMAR, gokula [Student] via TRNSYS-users wrote:
Dear Trnsys User, 

I tried to rebuild the TRNDLL.DLL following the steps stated in the programmer's guide (7.6.1. Rebuilding the TRNDll.dll with Intel Visual FORTRAN Composer). However, in the end, I could not reach a successful rebuilding. Here I have attached the screenshot of the VS studio environment of my solution file. Please have a look and give your possible suggestions for further processing.

Thanking you,
Gokula Manikandan Senthil Kumar 


Disclaimer:

This message (including any attachments) contains confidential information intended for a specific individual and purpose. If you are not the intended recipient, you should delete this message and notify the sender and The Hong Kong Polytechnic University (the University) immediately. Any disclosure, copying, or distribution of this message, or the taking of any action based on it, is strictly prohibited and may be unlawful.

The University specifically denies any responsibility for the accuracy or quality of information obtained through University E-mail Facilities. Any views and opinions expressed are only those of the author(s) and do not necessarily represent those of the University and the University accepts no liability whatsoever for any losses or damages incurred or caused to any party as a result of the use of such information.


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy System Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com