[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] trnsys :end of file encountered



Pu,

  It may be that the weather file is empty. Unfortunately when you run a simulation and the weather file that you have specified doesn't exist you get an error but a blank file is also created. The next time you run the simulation the weather file is found but can't be read correctly and so you can get this error. Check the weather file at the location you have specified and make sure that it is not 0kB in size.

  As a side note, if Type15 is reading a correct weather file and it gets to the end of the file it will just rewind the file back to the beginning and keep reading.

kind regards,

 David


On 09/14/2021 22:43, Huijie Pu via TRNSYS-users wrote:
Hello, 
I encountered an error in the simulation: end of file Encountered. It shows that there is an error in the weather file, I use type15-2, so I switch to another Type 15-6, the same error still occurs.I think the setup in Type15-6 is correct, how to solve this problem?
Pu


 


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com