Pouyan,

  Variable speed heat pump models (air-to-air, air-to-water, water-to-air, and water-to-water) will be available in an upcoming update to the TESS libraries. Because we have not yet set a firm release date, models are available individually at the moment. Please contact techsupport@tess-inc.com for details if you are interested.

kind regards,

 David


On 08/09/2021 08:41, Pouyan Talebizadehsardari (Staff) via TRNSYS-users wrote:

Dear Huseyin,

 

Thanks for your answer. However, in your paper, you used an air-to-air heat pump; however, as I have a radiator in my system, I need to use an air-to-water heat pump which there is only a single stage type in the TRNSYS TESS library.

 

Kind regards

Pouyan

 

From: Hüseyin Günhan Özcan <huseyin.ozcan@yasar.edu.tr>
Sent: 09 August 2021 14:27
To: Pouyan Talebizadehsardari (Staff) <Pouyan.Talebizadehsardari@brunel.ac.uk>
Cc: TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Subject: RE: air-to-water heat pump - Type 941

 

Dear Sardari,

 

You can use two-stage heat pump models to create low, nominal and high stages for the considered heat pump.

We had a publication for a two stage air source heat pump. Pls. see the shared link below.

 

https://www.sciencedirect.com/science/article/pii/S2210670721000482

 

Best regards,

 

Dr. Huseyin Gunhan OZCAN

 

From: TRNSYS-users <trnsys-users-bounces@lists.onebuilding.org> On Behalf Of Pouyan Talebizadehsardari (Staff) via TRNSYS-users
Sent: Monday, August 9, 2021 12:54 PM
To: TRNSYS-users@lists.onebuilding.org
Cc: Pouyan Talebizadehsardari (Staff) <Pouyan.Talebizadehsardari@brunel.ac.uk>
Subject: [TRNSYS-users] air-to-water heat pump - Type 941

 

Dear All,

 

I am modelling a house heated by radiators using an air-to-water heat pump. This model is based on user-supplied data files containing catalogue data for the capacity and power based on the inlet water temperature and air to the heat pump. As I understand, for a specific existed heat pump, the system should be tested for several inlet conditions (for example 5 different temperatures of water and air=25 case) and then create a new data file including the capacity and power. Am I correct?

My main question is that is it possible to consider additional characteristics of the heat pump in the model such as variable speed compressor so the system can be worked with a lower power when less heat is required for the radiators?

 

Thanks in advance

 

Best regards

 

*******************************************************************************

Pouyan Talebizadeh Sardari, BSc MSc PhD AFHEA

Centre for Sustainable Energy Use in Food Chains,

Institute of Energy Futures,

Brunel University London,

Kingston Lane, Uxbridge, Middlesex, UB8 3PH, UK

Email: pouyan.talebizadehsardari@brunel.ac.uk

 

Bu elektronik postada bulunan tum fikir ve gorusler ve ekindeki dosyalar sadece adres sahip/sahiplerine ait olup,
Yasar Universitesi bu mesajin icerigi ile ilgili olarak hic bir hukuksal sorumlulugu kabul etmez. Eger gonderilmesi
dusunulen kisi veya kurulus degilseniz, lutfen gonderen kisiyi derhal haberdar ediniz ve mesaji sisteminizden siliniz.


The information contained in this e-mail and any files transmitted with it are intended solely for the use of the
individual or entity to whom they are addressed Yasar University does not accept legal responsibility for the 
contents. If you are not the intended recipient, please immediately notify the sender and delete the message from your system.

 


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com