[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Parametric study



Patricia,

  Once you open the *.dck in TRNEdit, you can just change the block that reads:

EQUATIONS 2
AColl = 4.0
DHWDailyLoad = 200

to

CONSTANTS 2
AColl = 4.0
DHWDailyLoad = 200

While the TRNSYS engine and the parametric table part of TRNEdit make a distinction between CONSTANTS and EQUATIONS the Studio does not.

The access violation error is (I think) an old bug that has been fixed. I would recommend you contact your distributor to make sure that you are using the latest version.

kind regards,

 David


On 06/18/2021 08:54, Monzó, Patricia via TRNSYS-users wrote:

Hi,

 

My aim is to implement  a parametric study. My first question is:

What  is the difference between implementing in the Simulation studio  -> Calculate -> Parametric Study and in TRNEdit?

 

I have tried to  implement it  using TRNEdit according to the instruction in the Manual.

I have followed the example in the library  and I have a questions regarding the definitions of the Constants

 

Which I figured out that it comes from the file .tpf

 

 

When I  tried to implement it in a similar way I don’t get in .dck file the definition of the parameters of interest as Constants. They come as “equations”.

 

Did I miss any step in the preparation of the .dck file?

 

When I tried to run my file I  get and “access violation error”.

 

 

Thanks in advance,

/Patricia


_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com