Xavier,

It is possible that if you are using the debug form of the TRNDll and external dlls that the computer needs to have a microsoft run-time library installed.

Werner's question about other dependencies is a good one; are the Types simple self contained things or do they perhaps in turn call on libraries that may not be available?

Another interesting thing to try would beto try and run some TESS Libraries examples (if you have access to them) on this machine. Since the TESS Libraries are set up to load from external dlls, it would test whether the problem is fundamentally external dlls or whether it is your specific dlls.

kind regards,

 David


On 01/25/2021 02:06, Jobard Xavier wrote:

Dear David,

Many thanks for the answer.

I realize that my question was not specified correctly.
To answer your questions:

-          The dlls are correctly located

-          I am running Trnsys 17, so I should not have any compatibility problem between 32-bit and 64-bit dlls.

Can you help me further ?

Regards,

Xavier

 

De : David BRADLEY <d.bradley@tess-inc.com>
Envoyé : vendredi, 22 janvier 2021 17:12
À : TRNSYS users mailing list at OneBuilding.org <trnsys-users@lists.onebuilding.org>
Cc : Jobard Xavier <xavier.jobard@heig-vd.ch>
Objet : Re: [TRNSYS-users] error with dll found but is not loading the type on Virtual Machine Win10

 

Xavier,

  I think the first thing to check is to make sure that the dlls containing Types832 and 6139 are in the appropriate subdirectory of .\TrnsysXX\UserLib. The other thing that occurs to me is that there may be a mismatch between 64- and 32- bit versions. If those Types are compiled as 32-bit dlls they will not be found by the 64-bit Trnsys18 even if the files are in the correct location.

 I apologize if these suggestions are very basic!

kind regards,

 David

 

On 01/21/2021 10:13, Jobard Xavier via TRNSYS-users wrote:

Dear TRNSYS user,

 

I am trying to run a Trnsys deck with non-standard types (Type 832 and Type 6139)  on a virtual machine (win10).

 

A simple example (SDHW.dck) works fine. However my deck with type832 and type6139 which works fine on my laptop throws the errors but are actually listed as found further up the log file :

*** Fatal Error at time   :         0.000000

    Generated by Unit     : Not applicable or not available

    Generated by Type     :   832

    TRNSYS Message    105 : A TYPE was called in the TRNSYS input file but was either not linked into trndll.dll or was not found in an external dll. A dummy subroutine was called in its place. Please link the TYPE or remove it from the input file

    Reported information  :  Type832 could not be located in either the trndll.dll or in an external dll. Please relink theTRNDll.dll including this Type or make sure that an external DLL in the \UserLib\DebugDLLs and \UserLib\ReleaseDLLs folders contain the Type.

*** Fatal Error at time   :         0.000000

    Generated by Unit     : Not applicable or not available

    Generated by Type     :  6139

    TRNSYS Message    105 : A TYPE was called in the TRNSYS input file but was either not linked into trndll.dll or was not found in an external dll. A dummy subroutine was called in its place. Please link the TYPE or remove it from the input file

    Reported information  :  Type6139 could not be located in either the trndll.dll or in an external dll. Please relink theTRNDll.dll including this Type or make sure that an external DLL in the \UserLib\DebugDLLs and \UserLib\ReleaseDLLs folders contain the Type.

 

These 2 types are distributed by research institutes and were not recompiled in any way. Type 832 was used on several machines without problem before.

 

Can somebody help ?

 

http://correspondance.heig-vd.ch/assets/heig.png

Xavier Jobard
Ing. INSA Strasbourg

Collaborateur Ra&D

Institut de Génie Thermique (IGT)
Laboratoire d’énergétique solaire et de physique du bâtiment (LESBAT)

 

Prof. :

+41 24 557 28 17

Site web :

http://www.lesbat.ch



xavier.jobard@heig-vd.ch

 

 



_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA
 
P:+1.608.274.2577
d.bradley@tess-inc.com
 
http://www.tess-inc.com
http://www.trnsys.com
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
d.bradley@tess-inc.com

http://www.tess-inc.com
http://www.trnsys.com