Hi everyone, I have a problem. I am working in TRNSYS 17 with Type 99 (because we have weather data just in the format .99). I am using as well Type 69b in order to calculate
the sky temperature (TSKY) to link to Type 56. Here is the error message when I try to simulate the model: "The GetRadiationData routine has been called before the GlobalRadiationData array has been allocated" Do you know which is the problem? Here some data of my simulation model: -
Trnsys 17 -
Type 56 -
Type 99 as weather data reader -
Type 69b (that receives inputs from Type 99 and Type 33e) in order to calculate TSKY Thanks a lot Toni Calabrese, MSc. Wissenschaftlicher Projektmitarbeiter toni.calabrese@spf.ch |
toni.calabrese@ost.ch T +41 58 257 4827 SPF Institut für Solartechnik OST – Ostschweizer Fachhochschule Oberseestr. 10 | CH-8640 Rapperswil | Switzerland |
www.spf.ch |
www.ost.ch OST – Ostschweizer Fachhochschule ist der Zusammenschluss aus FHS St.Gallen, HSR Rapperswil und NTB Buchs. |