[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[TRNSYS-users] Type1288 IAM




Hey,

I am using Type1288 for modeling a Parabolic Trough Collector with single-axis tracking. In Type 1288, the IAM values are read from an external data file which contains the biaxial IAMs of the collector. For reading this data file, the longitudinal and transversal incident angle are needed. As far as I know, they are calculated by:

Tranverse = ATAN(SIN(Zenith angle)*SIN(ABS(Azimuth-SolarAzimuth))/COS(IncidentAngle_Beam))

Longitudinal = ABS(ATAN(TAN(Zenith angle)*COS(Azimuth-SolarAzimuth))-CollectorSlope)

For Tranverse=0° and Longitudinal=0° I would have expected an IAM of 1. However, Type1288 calculates a smaller one at this timestep.


Does anyone has experience using this Type or using a different type with a biaxial IAM input file and a similar problem occurred? Or have I missed something in my calculations?



Regards,