Julien,
Changing parameters to inputs requires that you modify the source code of the Type and recompile it into a new DLL. The source code for Type533 is in the .\Tess Models\SourceCode\ directory and TRNSYSv18 has a Fortran compiler built into it so in theory you should be able to use the TypeStudio to make the changes that you need. I say "in theory" because Type533 is a fairly complicated piece of code and it may not be a trivial process to modify and recompile.
kind regards,
David
Hello,I am using Type 533 Horizontal Cylinder Tank from Tess Library. I would like to define Surface Loss Coefficients as inputs instead of a parameters.I can't assign a variable name and I would prefer to avoid modifying the source code.Does anyone know a solution ?Thank you in advance,Best regards--Julien GAMBADE
Doctorant
Institut de Recherche Dupuy de Lôme (UMR CNRS 6027)
Centre de recherche Christian Huygens
Rue de Saint-Maudé - 56100 Lorient - France
julien.gambade@univ-ubs.fr
www.irdl.fr_______________________________________________ TRNSYS-users mailing list TRNSYS-users@lists.onebuilding.org http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- *************************** David BRADLEY Principal Thermal Energy Systems Specialists, LLC 3 North Pinckney Street - suite 202 Madison, WI 53703 USA P:+1.608.274.2577 F:+1.608.278.1475 d.bradley@tess-inc.com http://www.tess-inc.com http://www.trnsys.com