[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [TRNSYS-users] Type 15-3 doesn't work



The problem likely has to do with the header. In some epw files the time zone is a numerical value while in others it is written in text. If you can't just use v18 are must use v17 then I'd recommend trying to find an epw file that can be read in v17 and then comparing the headers of the two files. Chances are that the difference will be fairly evident.

regards,

 David


On 10/22/2020 21:18, Ricardo Gallegos via TRNSYS-users wrote:
Hi
I also use TYPE 15-3  in TRNSYS 17 since long and have not had any problem. Isn t your data file corrupt or somehow unreadable?
Regards

El jue., 22 oct. 2020 a las 5:20, Nidal Abdalla via TRNSYS-users (<trnsys-users@lists.onebuilding.org>) escribió:
Dear sir

I am trying to simulate my project using Energy+ weather data "EPW"  through type 15-3, but it doesn't work under TRNSYS 17, but it works properly under TRNSYS 18. How can I fix this problem for TRNSYS 17?
I attached the EPW file.


Best Regards 

Nidal Abdalla

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org

_______________________________________________
TRNSYS-users mailing list
TRNSYS-users@lists.onebuilding.org
http://lists.onebuilding.org/listinfo.cgi/trnsys-users-onebuilding.org
-- 
***************************
David BRADLEY
Principal
Thermal Energy Systems Specialists, LLC
3 North Pinckney Street - suite 202
Madison, WI  53703 USA

P:+1.608.274.2577
F:+1.608.278.1475
d.bradley@tess-inc.com

http://www.tess-inc.com